blueprint:
|
|
name: Bosch BTH-RA Radiator Control
|
|
homeassistant:
|
|
min_version: "2024.6.0"
|
|
description: >
|
|
Eine Automation zur automatischen Steuerung eines Bosch TRV Heizkörperthermostats.
|
|
domain: automation
|
|
author: Me
|
|
input:
|
|
trv:
|
|
name: Thermostat
|
|
description: Thermostat muss ein Bosch BTH-RA sein
|
|
selector:
|
|
entity:
|
|
multiple: false
|
|
filter:
|
|
- domain: climate
|
|
temperature_sensor:
|
|
name: Temperatursensor
|
|
selector:
|
|
entity:
|
|
multiple: false
|
|
filter:
|
|
- domain: sensor
|
|
device_class: temperature
|
|
heating_period_switch:
|
|
name: Heizperiode Switch
|
|
description: Optional - Input Boolean der angibt ob Heizperiode aktiv ist. Wenn nicht gesetzt, ist die Heizperiode immer aktiv.
|
|
default: 'none_selected'
|
|
selector:
|
|
entity:
|
|
multiple: false
|
|
filter:
|
|
- domain: input_boolean
|
|
window_section:
|
|
name: Fenster-/Türsensor Konfiguration
|
|
description: Konfiguration für den Fenster-/Türsensor.
|
|
collapsed: false
|
|
input:
|
|
window_sensor:
|
|
name: Fenster-/Türsensor (oder Gruppe)
|
|
selector:
|
|
entity:
|
|
multiple: false
|
|
filter:
|
|
- domain: binary_sensor
|
|
window_delay_open:
|
|
name: Fenster-/Türsensor Verzögerung
|
|
description: Zeit die das Fenster offen bleiben muss, um die den Radiator in den "Fenster offen"-Modus zu versetzen (Default = 30s)
|
|
default: 30
|
|
selector:
|
|
number:
|
|
mode: box
|
|
min: 0.0
|
|
max: 3600.0
|
|
unit_of_measurement: seconds
|
|
step: 1.0
|
|
window_delay_close:
|
|
name: Fenster-/Türsensor Verzögerung
|
|
description: Zeit die das Fenster geschlossen bleiben muss, um die den Radiator in den "Fenster geschlossen"-Modus zu versetzen (Default = 5s)
|
|
default: 5
|
|
selector:
|
|
number:
|
|
mode: box
|
|
min: 0.0
|
|
max: 3600.0
|
|
unit_of_measurement: seconds
|
|
step: 1.0
|
|
schedule_section:
|
|
name: Heizplan Konfiguration
|
|
description: Konfiguration der Heizpläne die für den Radiator berücksichtigt werden sollen
|
|
collapsed: false
|
|
input:
|
|
radiator_schedules:
|
|
name: Heizpläne
|
|
description: Alle Heizpläne die für den Radiator berücksichtigt werden sollen. Sind mehrere Schedules aktiv, wird der erste mit einem gültigen Slot verwendet.
|
|
default: []
|
|
selector:
|
|
entity:
|
|
multiple: true
|
|
filter:
|
|
- domain: switch
|
|
away_section:
|
|
name: Konfiguration für Abwesenheitsmodus
|
|
description: Konfiguration für das Absenken der Heizung im Abwesenheitsmodus eines Alarmsystems
|
|
collapsed: false
|
|
input:
|
|
alarm_control_panel:
|
|
name: Alarm Control Panel
|
|
description: Optional - Alarm Control Panel um Heizung abzusenken, wenn Alarm im Abwesendmodus ist
|
|
default: null
|
|
selector:
|
|
entity:
|
|
multiple: false
|
|
filter:
|
|
- domain: alarm_control_panel
|
|
away_temperature:
|
|
name: Abwesenheitstemperatur
|
|
description: Temperatur die eingestellt wird, wenn der Alarm im Abwesendmodus ist (Default = 18°C)
|
|
default: 18
|
|
selector:
|
|
number:
|
|
mode: box
|
|
min: 15.0
|
|
max: 25.0
|
|
unit_of_measurement: "°C"
|
|
step: 0.5
|
|
|
|
variables:
|
|
trv: !input trv
|
|
temperature_sensor: !input temperature_sensor
|
|
heating_period_switch: !input heating_period_switch
|
|
radiator_schedules: !input radiator_schedules
|
|
away_temperature: !input away_temperature
|
|
alarm_control_panel: !input alarm_control_panel
|
|
is_heating_period: >
|
|
{% if heating_period_switch is none or heating_period_switch == '' %}
|
|
true
|
|
{% else %}
|
|
{{ is_state(heating_period_switch, 'on') }}
|
|
{% endif %}
|
|
remote_temperature_entity: >
|
|
{% set entities = device_entities(device_id(trv)) %}
|
|
{% set remote_temperature_entity_id = namespace(id='') %}
|
|
{% for entity in entities %}
|
|
{% if 'remote_temperature' in entity %}
|
|
{% set remote_temperature_entity_id.id = entity %}
|
|
{% endif %}
|
|
{% endfor %}
|
|
{{ remote_temperature_entity_id.id }}
|
|
window_detection_entity: >
|
|
{% set entities = device_entities(device_id(trv)) %}
|
|
{% set window_detection_entity_id = namespace(id='') %}
|
|
{% for entity in entities %}
|
|
{% if 'window_detection' in entity %}
|
|
{% set window_detection_entity_id.id = entity %}
|
|
{% endif %}
|
|
{% endfor %}
|
|
{{ window_detection_entity_id.id }}
|
|
scheduled_temperature: >
|
|
{% set ns = namespace(current_temperature = none) %}
|
|
{% for schedule in radiator_schedules %}
|
|
{% if states(schedule) == 'on' and state_attr(schedule, 'current_slot') is not none %}
|
|
{% set current_slot = state_attr(schedule, 'current_slot') %}
|
|
{% set actions = state_attr(schedule, 'actions') %}
|
|
{% if actions is not none and actions | length > current_slot %}
|
|
{% set action = actions[current_slot] %}
|
|
{% if action.data.temperature is defined and action.data.temperature | is_number %}
|
|
{% set ns.current_temperature = action.data.temperature %}
|
|
{% break %}
|
|
{% endif %}
|
|
{% endif %}
|
|
{% endif %}
|
|
{% endfor %}
|
|
{{ ns.current_temperature }}
|
|
target_temperature: >
|
|
{% if alarm_control_panel and is_state(alarm_control_panel, 'armed_away') %}
|
|
{{ away_temperature }}
|
|
{% elif scheduled_temperature is not none %}
|
|
{{ scheduled_temperature }}
|
|
{% else %}
|
|
{{ away_temperature }}
|
|
{% endif %}
|
|
|
|
triggers:
|
|
- platform: state
|
|
entity_id:
|
|
- !input window_sensor
|
|
from: "off"
|
|
to: "on"
|
|
for: !input window_delay_open
|
|
id: FENSTER_OPEN
|
|
- platform: state
|
|
entity_id:
|
|
- !input window_sensor
|
|
from: "on"
|
|
to: "off"
|
|
for: !input window_delay_close
|
|
id: FENSTER_CLOSED
|
|
- platform: time_pattern
|
|
# Synce Temperatur alle 20 Minuten (Teiler von 60)
|
|
minutes: "/20"
|
|
id: SYNC_TEMPERATURE
|
|
- platform: state
|
|
entity_id: !input temperature_sensor
|
|
id: TEMP_CHANGED
|
|
- platform: state
|
|
entity_id: !input alarm_control_panel
|
|
to: "armed_away"
|
|
id: ALARM_ARMED_AWAY
|
|
- platform: state
|
|
entity_id: !input alarm_control_panel
|
|
from: "armed_away"
|
|
to: "disarmed"
|
|
id: ALARM_DISARMED_AWAY
|
|
- platform: state
|
|
entity_id: !input heating_period_switch
|
|
to: "on"
|
|
id: HEATING_PERIOD_ON
|
|
- platform: state
|
|
entity_id: !input heating_period_switch
|
|
to: "off"
|
|
id: HEATING_PERIOD_OFF
|
|
|
|
actions:
|
|
- choose:
|
|
# Alle bestehenden Aktionen nur ausführen wenn Heizperiode aktiv ist
|
|
- conditions:
|
|
- condition: template
|
|
value_template: "{{ is_heating_period }}"
|
|
sequence:
|
|
# setze Fenster auf offen/geschlossen
|
|
- choose:
|
|
- conditions:
|
|
- condition: trigger
|
|
id:
|
|
- FENSTER_OPEN
|
|
- condition: template
|
|
value_template: >
|
|
{{ is_state(window_detection_entity, 'off') }}
|
|
sequence:
|
|
- service: switch.turn_on
|
|
target:
|
|
entity_id: "{{ window_detection_entity }}"
|
|
alias: Setze Fenster auf offen
|
|
- conditions:
|
|
- condition: trigger
|
|
id:
|
|
- FENSTER_CLOSED
|
|
- condition: template
|
|
value_template: >
|
|
{{ is_state(window_detection_entity, 'on') }}
|
|
sequence:
|
|
- service: switch.turn_off
|
|
target:
|
|
entity_id: "{{ window_detection_entity }}"
|
|
- if:
|
|
- condition: template
|
|
value_template: >
|
|
{{ target_temperature is not none and target_temperature | is_number }}
|
|
then:
|
|
- service: climate.set_temperature
|
|
target:
|
|
entity_id: !input trv
|
|
data:
|
|
temperature: "{{ target_temperature | float }}"
|
|
alias: Setze Fenster auf geschlossen und setze Solltemperatur auf Wert aus Zeitplan (wenn vorhanden)
|
|
alias: Fensterstatus Änderung
|
|
# temperature sensor sync
|
|
- choose:
|
|
- conditions:
|
|
- condition: trigger
|
|
id:
|
|
- TEMP_CHANGED
|
|
- condition: template
|
|
value_template: >
|
|
{{ temperature_sensor is defined and states(temperature_sensor) | is_number }}
|
|
sequence:
|
|
- service: number.set_value
|
|
data:
|
|
value: "{{ states(temperature_sensor) | float }}"
|
|
target:
|
|
entity_id: "{{ remote_temperature_entity }}"
|
|
alias: Synchronisiere Temperatur am TRV (bei Änderung)
|
|
- conditions:
|
|
- condition: trigger
|
|
id:
|
|
- SYNC_TEMPERATURE
|
|
- condition: template
|
|
value_template: >
|
|
{{ temperature_sensor is defined and states(temperature_sensor) | is_number }}
|
|
- condition: template
|
|
value_template: >
|
|
{{ (now() - states[temperature_sensor].last_changed).total_seconds() > 1199 }}
|
|
sequence:
|
|
- service: number.set_value
|
|
data:
|
|
value: "{{ states(temperature_sensor) | float }}"
|
|
target:
|
|
entity_id: "{{ remote_temperature_entity }}"
|
|
alias: Synchronisiere Temperatur am TRV (zeitbasiert, wenn länger als 20min unverändert)
|
|
alias: Temperatursynchronisation
|
|
# setze Solltemperatur basierend auf Alarm-Status
|
|
- choose:
|
|
- conditions:
|
|
- condition: trigger
|
|
id:
|
|
- ALARM_ARMED_AWAY
|
|
- ALARM_DISARMED_AWAY
|
|
sequence:
|
|
- if:
|
|
- condition: template
|
|
value_template: >
|
|
{{ target_temperature is not none and target_temperature | is_number }}
|
|
then:
|
|
- service: climate.set_temperature
|
|
target:
|
|
entity_id: !input trv
|
|
data:
|
|
temperature: "{{ target_temperature | float }}"
|
|
alias: Setze Solltemperatur basierend auf Alarm-Status
|
|
alias: Solltemperatur setzen
|
|
alias: Aktionen während Heizperiode
|
|
# Heizperiode Switch Aktionen
|
|
- conditions:
|
|
- condition: trigger
|
|
id:
|
|
- HEATING_PERIOD_ON
|
|
- HEATING_PERIOD_OFF
|
|
sequence:
|
|
- choose:
|
|
- conditions:
|
|
- condition: trigger
|
|
id:
|
|
- HEATING_PERIOD_ON
|
|
sequence:
|
|
- service: climate.set_hvac_mode
|
|
target:
|
|
entity_id: !input trv
|
|
data:
|
|
hvac_mode: "heat"
|
|
- if:
|
|
- condition: state
|
|
entity_id: !input window_sensor
|
|
state: "on"
|
|
then:
|
|
- service: switch.turn_on
|
|
target:
|
|
entity_id: "{{ window_detection_entity }}"
|
|
- if:
|
|
- condition: template
|
|
value_template: >
|
|
{{ target_temperature is not none and target_temperature | is_number }}
|
|
then:
|
|
- service: climate.set_temperature
|
|
target:
|
|
entity_id: !input trv
|
|
data:
|
|
temperature: "{{ target_temperature | float }}"
|
|
alias: Heizperiode aktiviert - Setze Modus auf heat, synchronisiere Fensterstatus und Solltemperatur
|
|
- conditions:
|
|
- condition: trigger
|
|
id:
|
|
- HEATING_PERIOD_OFF
|
|
sequence:
|
|
- service: switch.turn_off
|
|
target:
|
|
entity_id: "{{ window_detection_entity }}"
|
|
- service: climate.set_hvac_mode
|
|
target:
|
|
entity_id: !input trv
|
|
data:
|
|
hvac_mode: "off"
|
|
alias: Heizperiode deaktiviert - Setze Fenster geschlossen und Modus auf off
|
|
alias: Heizperiode Switch Änderung
|
|
alias: Heizperiode Switch Aktionen
|
|
alias: Hauptsteuerung |