remove sections

This commit is contained in:
2025-12-07 11:33:43 +01:00
parent 888ab99b3e
commit 8a9e355d74

View File

@@ -8,78 +8,63 @@ blueprint:
domain: automation domain: automation
author: Me author: Me
input: input:
radiator_settings: trv:
name: Radiator Konfiguration name: Thermostat
description: Konfiguration für den Bosch BTH-RA Radiator description: Thermostat muss ein Bosch BTH-RA sein
collapsed: false selector:
input: device:
trv: multiple: false
name: Thermostat filter:
description: Thermostat muss ein Bosch BTH-RA sein - integration: MQTT
selector: - manufacturer: Bosch
device: - model_id: BTH-RA
multiple: false
filter:
- integration: MQTT
- manufacturer: Bosch
- model_id: BTH-RA
entity:
- domain: climate
window_config:
name: Fenster-/Türsensor Konfiguration
description: Konfiguration für den Fenster-/Türsensor.
collapsed: true
input:
window_sensor:
name: Fenster-/Türsensor (oder Gruppe)
selector:
entity: entity:
multiple: false - domain: climate
filter: window_sensor:
- domain: binary_sensor name: Fenster-/Türsensor (oder Gruppe)
window_delay_open: selector:
name: Fenster-/Türsensor Verzögerung entity:
description: Zeit die das Fenster offen bleiben muss, um die den Radiator in den "Fenster offen"-Modus zu versetzen (Default = 30s) multiple: false
default: 30 filter:
selector: - domain: binary_sensor
number: window_delay_open:
mode: box name: Fenster-/Türsensor Verzögerung
min: 0.0 description: Zeit die das Fenster offen bleiben muss, um die den Radiator in den "Fenster offen"-Modus zu versetzen (Default = 30s)
max: 3600.0 default: 30
unit_of_measurement: seconds selector:
step: 1.0 number:
window_delay_close: mode: box
name: Fenster-/Türsensor Verzögerung min: 0.0
description: Zeit die das Fenster geschlossen bleiben muss, um die den Radiator in den "Fenster geschlossen"-Modus zu versetzen (Default = 5s) max: 3600.0
default: 5 unit_of_measurement: seconds
selector: step: 1.0
number: window_delay_close:
mode: box name: Fenster-/Türsensor Verzögerung
min: 0.0 description: Zeit die das Fenster geschlossen bleiben muss, um die den Radiator in den "Fenster geschlossen"-Modus zu versetzen (Default = 5s)
max: 3600.0 default: 5
unit_of_measurement: seconds selector:
step: 1.0 number:
remaining_config: mode: box
name: Weitere Konfiguration min: 0.0
description: Sonstige Konfigurationen für die Automation max: 3600.0
collapsed: true unit_of_measurement: seconds
input: step: 1.0
temperature_sensor: temperature_sensor:
name: Temperatursensor name: Temperatursensor
selector: selector:
entity: entity:
multiple: false multiple: false
filter: filter:
- domain: sensor - domain: sensor
device_class: temperature device_class: temperature
radiator_schedules: radiator_schedules:
name: Heizpläne name: Heizpläne
description: Alle Heizpläne die für den Radiator berücksichtigt werden sollen description: Alle Heizpläne die für den Radiator berücksichtigt werden sollen
selector: selector:
entity: entity:
multiple: true multiple: true
filter: filter:
- domain: switch - domain: switch
variables: variables:
trv: !input trv trv: !input trv